Description

The ICM450 is a 3-Phase Monitor with 25-fault memory, LCD setup, diagnostics, and fault identification. Digital three-phase line voltage monitor offering full line AND load side protection; fully programmable with 25-fault memory; 190-630 VAC (18-240 control VAC). Identifies front and back side faults. Protects against: voltage unbalance, high/low voltage, phase loss, phase reversal, faulty power, incorrect sequencing, and rapid short cycling.

The ICM450 3-Phase Monitor 25-Fault Memory comes packed with features. To begin with, it has a reliable, high-temperature LCD. This simplifies the system setup and diagnostics. It indicates the condition of the incoming line voltage, fault conditions, system set points, and other user adjustments. It features a temperature of -20°C to +75°C (-4°F to + 167°F).

Also, it has a simultaneous voltage display, which is an ICM exclusive. You can view all 3 phases without needing to scroll through readouts. Featured is also a fully adjustable variable; the user can easily set and adjust variables in setup mode. Included are a line voltage: 190 to 600 VAC; voltage    unbalance: 2 to 20%; delay on break period: 0 to 10 minutes; fault interrogation: 0 to 15 seconds; over/under voltage: 2 to 25%; reset modes: AUTO or 0 to 10 retries; and control mode: ON or OFF.

Furthermore, it has 25 fault memory and storage displayed on the LCD. As well as ultra-bright LED indicators that show the current mode, for example, set up the LED, Control voltage LED, Load energized LED, and Fault LED. Lastly, it’s easy to install and configure. It has a simple 7-step push button for the setup. It also features a writing diagram on the unit. An installation and application guide are also included.

  • ICM450 3-Phase Monitor with 25-Fault Memory
  • Reliable, high temperature LCD display
  • Simplifies system setup and diagnostics. Indicates condition of incoming line voltage, fault conditions, system setpoints and other user adjustments.
  • Temperature: -20°C to +75°C (-4°F to + 167°F)
  • Simultaneous voltage display (an ICM exclusive)
  • View all 3 phases, no need to scroll through readouts.
  • Fully adjustable variables
  • User may easily set and adjust variables in SETUP mode
  • Line voltage: 190 to 600 VAC
  • Voltage unbalance: 2 to 20%
  • Delay on break period: 0 to 10 minutes
  • Fault interrogation: 0 to 15 seconds
  • Over/under voltage: 2 to 25%
  • Reset modes: AUTO or 0 to 10 retries
  • Control mode: ON or OFF
  • 25-fault memory and storage
  • Clearly displayed on LCD
  • Ultra bright LED indicators
  • Shows current mode
  • Setup LED
  • Control voltage LED
  • Load energized LED
  • Fault LED
  • Easy to install and configure
  • Simple 7-step push-button setup
  • Wiring diagram on unit
  • Installation and application guide included
ICM450 3-Phase Monitor with 25-Fault Memory
Input
Line Voltage : Universal (190-630 VAC)
Frequency : 50/60 Hz
Output
Type : Relay
Form : SPDT
Voltage Range : Up to 240 VAC (maximum: 10 amps)
Frequency : 50/60 Hz
Control Operating Temperature
Operating Temperature : -40ºC to +75ºC (-40ºF to +167ºF)
Storage Temperature : -40ºC to +85ºC (-40ºF to +185ºF)
LCD Operating Temperature
Operating Temperature : -20ºC to +75ºC (-4ºF to +167ºF)
Phase Unbalance Protection
Voltage Unbalance : 2-25% adjustable
Over/Under Protection
Under Voltage : 2-25% adjustable
Over Voltage : 2-25% adjustable
Phase Loss Protection
Phase Loss condition = <25% of nominal for any given phase. System will shut down and a fault will be recorded should this condition occur :
Delay on Break Timer
Control Voltage : 18-240 VAC
Time Delay : 0-10 minutes adjustable
Fault Interrogation Delay
Time Delay : 0-15 seconds adjustable
Mechanical
Mounting : Surface mount using (2) #8 screws
Termination : Screw terminals
Weight : 12 ounces (341 grams)
Dimensions : : 6.5” x 4.25” x 1.4” (16.5 x 10.8 x 3.5 cm)