Instantly shop and save 5%-20%. Learn more.
$185.30
On Backorder. Allow an extra 2-7 days for delivery.
Need Help? Speak with our HVAC and tools experts. Call or text (786) 239-7444.
The Fieldpiece HS33 Expandable Manual Ranging Stick Multimeter HVAC/R Full Featured is a great entry-level modular multimeter. Like every Fieldpiece meter, it’s packed with the features and functions HVACR technicians need to get the job done. The ergonomic shape fits firmly and naturally in your hand while testing. The magnetic hanger, detachable test leads, and alligator clip probe tips allow you to perform tests hands-free.
Because this Fieldpiece HS33 multimeter has all the basics and more for a great price, many schools prefer it for their HVACR students. The rugged rubberized bumpers help this meter withstand harsh conditions in the field.
All accessory heads slide directly on top of the Fieldpiece Multimeter so that you can test a wider variety of parameters than in a single meter. The modular expandability of the Fieldpiece meter makes it so you don’t have to buy expensive meters to perform additional measurements like airflow, amps, static pressure, vacuum, and many more. There are 15 different accessory heads to choose from.
Fieldpiece Expandable Manual Ranging Stick Multimeter for HVAC/R measures Continuity, Capacitance, AC/DC Volts, Diode Test, Resistance, and Temperature. It is equipped with magnetic hallows all-hands-frees free testing to do the job more effectively. The Fieldpiece HS33 Expandable Manual Ranging Stick Multimeter also features Non-contact voltage and Auto power off to conserve battery life.
Fieldpiece HS33 Expandable Manual Ranging Stick Multimeter for HVAC/R | |
Display : | 3½ digit liquid crystal display (LCD) with a maximum reading of 1999. |
Overrange : | "OL" mark indication. |
Auto power off : | 60 minutes. |
Operating environment : | 32 to 122°F (0 to 50°C) at <70% R.H. |
Storage temperature : | -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed. |
Accuracy : | Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity. |
Temperature Coefficient : | 0.1×(specified accuracy) per °F/°C. (32 to 64°F (0 to 18°C), 82 to 122°F (28 to 50°C)). |
Power : | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22. |
Battery life : | 300 hours typical with alkaline. |
Accessories : | One pair test leads, one pair alligator clips, k-type thermocouple (HS33), 9V battery (installed), and operating instructions. |
Safety : | UL, CE, Cat III 600V, UL3111, IEC/EN61010-1, C-Tick certified. |
Diode test | |
Test current : | ∼1.0mA |
Accuracy : | ±(1.5% rdg + 3 dgts) |
Open circuit volts : | 3.0VDC typical |
Overload protection : | 500VDC or AC rms |
Continuity | |
Audible indication : | Less than 100Ω |
Response time : | 100ms |
Status indicator : | Green LED will be on continuously. |
Overload protection : | 500VDC or AC rms |
Capacitance | |
Range : | 200μF |
Resolution : | 0.1μF |
Accuracy : | ±(3% rdg + 5 dgts) |
Overload protection : | 500VDC or AC rms |
DC volts | |
Ranges : | 200mV, 2000mV, 20V(HS32), 200V |
Resolution : | 0.1mV |
Accuracy : | ±(0.5% rdg + 1 dgt) |
Input impedance : | 560kΩ on V inputs, 10MΩ on mV input |
Overload protection : | 600VDC or AC rms, 500VDC/350VAC rms 15 sec on 200mV range |
Transient protection : | 6kV for 10μ sec |
AC volts (50Hz - 500Hz) | |
Ranges : | 200mV, 200V, 600V |
Resolution : | 0.1mV |
Accuracy : | ±(1.2% rdg + 3 dgts) ±(2.0% rdg + 5 dgts) on 600V range |
Input impedance : | 560kΩ on V input, 10MΩ on mV input |
Overload protection : | 600V DC or AC rms |
Transient protection : | 6kV for 10μ sec |
Resistance | |
Ranges : | 200Ω, 200kΩ |
Resolution : | 0.1Ω |
Accuracy : | ±(1.0% rdg + 4 dgts) |
Open circuit volts : | 0.3VDC typical, (3.0VDC on 200Ω range) |
Overload protection : | 500VDC or AC rms |
Temperature (HS33) | |
Range : | -30 to 200°F (-34 to 93°C) |
Resolution : | 0.1°F/°C |
Accuracy : | ±1°F, 32 to 120°F (0 to 48°C), ±1% + 1.5°F, -4 to 200°F (-20 to 93°C), ±2% + 3°F, -30 to -4°F (-34 to -20°C). |
Sensor type : | K-type thermocouple |
Overload protection : | 60 VDC or 30 VAC rms |
VAC, VDC, AAC, Temperature, & Capacitance (MFD).
This Fieldpiece multimeter is warranted against defects in material or workmanship for one year from date of purchase.